FTS .FGA-10V 50PPM Class Fluxgate High-Precision Current Sensor

Used for high-precision DC, AC, and pulse current measurement, with optimal measurement accuracy up to 10PPM 。

 

 

 

 

Features

application

Advantages

standard

l   High-precision zero-flux closed-loop control

l   DB9 Lockable Connector

l   LED status display

l   The metal casing is used for electromagnetic shielding and heat dissipation.

l   Wide temperature range design, operating temperature from -40 to 90

l   Scanner, MRI

l   Converter, Inverter

l   Aerospace , satellites, rockets

l   Verification and Calibration Equipment

l   High-speed trains, subways, and trolleybuses

l   Original and secondary border isolation measurement

l   50PPM measurement accuracy, ±10V voltage output.

l   Excellent linearity and extremely low temperature drift.

l   Wide bandwidth and low response time

l   Professional magnetoelectric design, strong resistance to electromagnetic interference

l   Excellent testing capabilities

l   IEC 61010-1

l   IEC 61000-6-2:2016

l   IEC 61000-6-3:2006

l   IEC 61010-2-030:2017

l   IEC 60112

 

Environmental and mechanical properties

project

parameter

Ambient operating temperature / T A

-40 to 90

Storage ambient temperature / T S

-40 to 90

Relative humidity /RH

20%RH to 80%RH

mechanical shock protection level

IP54

 

Insulation properties

project

Test conditions

parameter

Isolation voltage / V d

50Hz, 1min

5kV

Transient isolation withstand voltage / V w

50us

10kV

Creepage distance / d Cp

 

11mm

Electrical clearance distance / d Ci

 

11mm

Compared to the tracking index / CTI

IEC-60112

600V

 

Electrical parameters

project

Test conditions

Minimum value

nominal value

Maximum value

unit

Operating voltage / V C

±14.2

±15

±15.8

V

Static power consumption current / I PWR

 

± 4 0

mA

Accuracy / X G

Input DC, 25±10ºC

5 0

ppm

Linearity / εL

10

ppm

Temperature stability / T C

0.5

ppm/K

Time stability / T T

0.5

ppm/month

Power supply anti-interference/ TV

1

ppm/V

Dynamic response time / t r

di/dt = 100 A/ μs , rising to 90% IPN

7

μs

Voltage change rate / dv / dt

1.5

V / μs

Bandwidth (-3dB)/F

0

500

kHz

Zero-point offset voltage / V OT

Full temperature range

± 10

μ V

 

Selection list

0 to ±800A Selection List 1

model

FGA100-10V

FGA200-10V

FGA400-10V

FGA500-10V

FGA800-10V

Primary side rated DC/I DC

±10 0A

±20 0A

±40 0A

± 500A

±800A

Primary side rated AC RMS value / I AC

70A

141A

282A

353A

567A

Primary overload current / IPM

± 120A

± 240A

± 480A

± 600A

±960A

Transformer

( Primary edge: Secondary edge ) V KN

100mV/A

50mV /A

25mV/A

20mV/A

12.5mV/A

Rated output voltage / V S N

±10V

±10V

±10V

±10V

±10V

Installation method

Disc installation

aperture

35mm

45mm

External structure

Figure 4

Figure 5

 

 

±1000 to ±3000A Selection List 2

model

FGA1000-10V

FGA1500-10V

FGA2000-10V

FGA3000-10V

 

Primary side rated DC/I DC

± 1000A

± 1500A

±2000A

±3000A

 

Primary side rated AC RMS value / I AC

707A

1060A

1414A

2121A

 

Primary overload current / IPM

± 1200A

± 1600A

±2400A

±3600A

 

Transformation ratio ( primary side: secondary side ) V KN

10mV/A

6.66 mV/A

5 mV/A

3.33 mV/A

 

Rated output voltage / V S N

±10V

±10V

±10V

±10V

 

Installation method

Disc installation

aperture

45mm

72mm

72mm

External structure

Figure 5

Figure 6

Figure 7

 

External dimensions and specifications

Figure 4 Outline drawing of the 0 to ±400A current sensor

Figure 5 Outline drawing of ±500 to ±1500A current sensor

Figure 6 Outline drawing of ±2000 to ±3000A current sensor